2. Bridged Mode WanLink with Virtual Ports/Redirect Devices

Goal: Setup a Bridged Mode WanLink using RDDs (Redirect Devices). Return to LANforge-ICE Cookbook

In this test scenario, a LANforge-ICE WanLink is created in Bridged Mode using Redirect Devices to illustrate an example of how to send LANforge-FIRE traffic to yourself through LANforge-ICE. This is useful when physical ports are in short supply and a proof-of-concept test is needed.

  1. Setup a Netsmith Connection.

    A: Go to the Status tab and click Netsmith
    B: Right-click inside the Netsmith window and select New Connection
    C: Accept defaults, Auto Create everything and click OK

    NOTE:   The new connection consists of two pairs of Redirect Devices, Port 1A, 1B and Port 2A, 2B and a WanLink. The new connection is not created until you click the Apply button in the Netsmith window.

    D: Apply the new connection

    NOTE:   The new connection is created and has a Bridged Mode WanLink between Redirect Device ports 1B and 2B which are shown as smaller, green squares (B-Ports) connected by a vertical bar (WanLink).

  2. Setup the WanLink.

    A: Right-click the WanLink and select Modify WanLink
    B: Verify that the B-side ports of the Redirect Device pairs (rddVR0b and rddVR1b) are configured

    NOTE:   Be sure to set the impairment, if any, and transfer rate

    • Click OK when done

    C: Right-click on the WanLink and select Toggle WanLink to Running (green)

  3. Setup the ports.

    A: Right-click port rddVR0 and select Modify Port
    B: Assign an IP address and Network Mask to rddVR0
    C: Right-click port rddVR1 and select Modify Port
    D: Assign an IP address and Network Mask to rddVR1

    NOTE:   As an alternate method to set Network Mask, enter a / followed by the number of mask bits after the IP address. In this case, /24 is equivalent to 255.255.255.0

    E: Select the 'IPv4s' checkbox at the bottom of the Netsmith window to verify port configuration
    F: Go to the Port Mgr tab to verify port configuration

    NOTE:   The Bridged Mode WanLink is connected between rddVR0b and rddVR1b which both have 0.0.0.0 IP addresses

  4. Create a Layer-3 Connection.

    A: Go to the Layer-3 tab and click Create
    B: The RDD-FIRE connection will use the A-side ports of the Redirect Device pairs

    NOTE:   These are the ports rddVR0 and rddVR1 that were assigned IP addresses in step 2

    C: Verify the Layer-3 connection was created

  5. Run LANforge-FIRE to yourself through LANforge-ICE!

    A: Select the Layer-3 Cross Connect and click Start
    B: Click Display to show the Layer-3 Cross Connect details
    C: Go to the Status tab and click Netsmith to view the graphical representation of the setup
    D: Right-click on the WanLink and select Display WanLink to display the WanLink details

  Email Candela Technologies at: support@candelatech.com if you have any questions or suggestions.

 


Candela Technologies, Inc., 2026 Main Street, Suite A, P.O. Box 3285, Ferndale, WA 98248, USA